AEG VX9 vacuum cleaner. The electronics must be removed.

The vacuum cleaner switches off immediately...

iFixit Library AEG VX9 Staubsauger Moderate 30 minutes Guide 214264
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

The vacuum cleaner switches off immediately after 1 second. The electronics must be removed in order to measure the components. A capacitor power supply is installed on the PCB to provide the control chip with low-voltage direct current. The relevant capacitor had only 0.06 uF instead of 0.33 uF. As a result, there was only 2.8 V at the 16V capacitor. This is not enough for the control chip. After replacing the 0.33 uF capacitor, the control chip had sufficient voltage again and the vacuum cleaner worked perfectly. The biggest challenge was opening the device. The way the cover for the electronics is attached was previously unknown to me. Without screws, there is no indication for disassembly. The small holes through which you have to push the fastening tabs are too inconspicuous. Conclusion: Simple fastening for the cover, but almost impossible to remove the cover without a guide.

Step 1

Removing the lid

  • Insert a flathead screwdriver into the inside of the lid hinge and pry outward.
  • Pry the lid off on both sides and pull it forward to remove it.
Step 2

Remove the cover

  • Use a rod about 2 mm thin, press 2 cm into the hole, and bend the tab away.
  • At the same time, pry up the plate with a flathead screwdriver.
  • This tab must be hit. It is not very easy.
  • Perform this action on the left and right sides.
Step 3

Capacitors

  • 16V capacitor.
  • X2 MKP 0.33 uF 250 V (or more) film capacitor