Microsoft Bluetooth Ergonomic Mouse Optical Sensor Lens Replacement

This guide explains how to replace the optical...

iFixit Library Microsoft Bluetooth Ergonomic Mouse Moderate 20 minutes Guide 215193
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide explains how to replace the optical sensor lens in a Microsoft Bluetooth Ergonomic Mouse if the sensor is damaged or no longer functioning properly. The optical sensor detects surface movement and translates that motion into cursor movement on your computer. A faulty sensor may cause the cursor to move inconsistently, inaccurately, or not at all. Before proceeding, inspect the sensor opening for dust, debris, or surface damage that may be interfering with tracking. Test the mouse on multiple surfaces and verify your motion settings to confirm the optical sensor is the source of the issue. Before beginning, power off the mouse and disconnect it from any external power source.

Step 1

Repair step

  • Remove the battery cover and take out both AAA batteries from the mouse.
  • At this point, the mouse should have no power source and be safe to work on.
Step 2

Repair step

  • Insert a thin pry tool beneath the seam near the left and right click buttons.
  • Slide the pry tool toward the rear of the mouse while keeping the tool underneath the upper shell clips.
  • Gently release the retaining clips securing the top shell.
  • Continue working around the shell until the top cover separates from the lower housing.
Step 3

Repair step

  • Remove the three 7.1 mm T6 Torx screws securing the inner shell.
Step 4

Repair step

  • Open the inner shell carefully from left to right to access the internal circuits.
  • Do not pull on the wires connecting the upper and lower shell components.
Step 5

Repair step

  • Use tweezers to lift and disconnect the two JST connectors secured to the motherboard.
  • Grip the white connectors, not the wires.
Step 6

Repair step

  • Use tweezers to disconnect the battery power supply connector from the motherboard.
Step 7

Repair step

  • Remove the two 7.1 mm Phillips #00 screws securing the button board.
  • Remove the three 4.1 mm Phillips #00 screws securing the motherboard to the housing.
Step 8

Repair step

  • Carefully lift the circuit board out of the mouse housing.
  • Use angled tweezers to remove the optical sensor lens from the lower housing.