FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Check Transformer Resistances & Voltages

⚠️ WARNING: High Voltage / Mains Power Safety:...

iFixit Library REL T5 Moderate No estimate Guide 221116
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

⚠️ WARNING: High Voltage / Mains Power Safety DANGER: This repair involves exposing components connected to mains voltage (110V–240V AC). Mains voltage carries enough energy to cause severe electrical shock, serious injury, or death. If you are uncomfortable working around high-voltage electronics, stop here and consult a professional. Before troubleshooting anything else, make sure your supply power is in order.

Step 1

Remove screws

  • Place the subwoofer on it legs to protect the driver. Be careful not to touch the driver/speaker on the bottom when you handle the case.
  • Using the 3mm hex tool, remove only the outer rim of screws, starting from the bottom.
  • Make sure to support the plate amp by gripping the heat sink.
  • Remove the top screws. Be aware: the heavy transformer is located at the top. Removing the top screws will probably make the plate amp tilt out of the case.
  • Using the heatsink, carefully lift the plate amp out of the case. Again: it's heavier than you might expect!
Step 2

Disconnect the driver

  • The plate amp is still connected to the driver via faston connectors. I found it easiest to disconnect the driver connectors, but removing them from the amplifier side works equally well.
Step 3

Remove plate amp

  • You've now removed the plate amp. Set it aside on the heatsink side. The height of the heatsink will make sure that the controls are not damaged.
  • Now is a good time to check the voltage rails for residual voltage. Everything after the rectifier bridge should be <45V, but always take appropriate precautions when it comes to mains powered devices.
Step 4

Snip all connecting trywraps

  • Snip all tywraps, such that all cables can be manipulated freely.
Step 5

Disconnect connectors

  • Disconnect all connectors that tie to the transformer
  • Make sure that all leads can be manipulated freely.
Step 6

Loosen screws

  • Start loosening the screws on the back using the m3 hex tool
  • Don't remove them fully, yet though.
Step 7

Remove screws

  • Turn the amp on it's back.
  • Remove the nuts from the screws that where loosened on the back.
  • Remove the philips screws using a #2.
Step 8

Loosen dampening rubber

  • Loosen the dampening rubber by running a Halberd Spudger underneath it.
  • The rubber is not adhered to the aluminium and is pretty tough, so a moderate amount of force is allowed.
Step 9

Remove transformer

  • You can now remove the transformer from the plate. Be careful not to damage the controls on the plate now that the assembly is a lot lighter.
Step 10

Primary side connections

  • First (marked CN1)
  • White
  • Blue
  • Brown
  • Second (marked CN3)
  • Black
  • Orange
Step 11

Secondary side connection

  • Connector
  • Gray
  • White
  • Gray
Step 12

Primary side resistances and voltages

  • Resistances
  • Black - White: 5.7Ω
  • Orange - Blue: 5.5Ω
  • Blue - Brown: 0Ω
  • European version: Orange - Black Shorted on Mains PCB
  • Voltages
  • Blue - White: 230VAC
Step 13

Seconday side resistances and voltages

  • Resistances
  • Gray - Gray: 1.9Ω
  • White - Gray (any): 1.1Ω
  • Voltages
  • White - Gray (any): 43VAC