If your Ventline PH Series RV range hood (model S0721, 12V DC, 100 CFM) has an exhaust fan that won't turn on at all, use this guide to replace the fan motor. The fan motor draws air up through the range hood and out through the roof vent, clearing smoke, steam, and cooking odors from the RV's galley. When the motor fails, the fan won't spin at any switch setting, even though the range hood's light and other functions may still work normally. Before starting, disconnect 12V DC power to the range hood at the RV's breaker or fuse panel. The range hood runs on the RV's low-voltage house battery system, but you should still cut power before disconnecting any wiring to avoid a short near the cabinetry above the stove.

Step 1

Repair step

  • Remove the five Phillips #1 screws securing the metal fan housing to the range hood frame.
Step 2

Repair step

  • Pull up on the center of the plastic fan blade housing to lift it off the motor shaft.
Step 3

Repair step

  • Disconnect the two wire connectors from the back of the fan motor.
Step 4

Repair step

  • Flip the housing over, then remove the two Phillips #00 screws securing the motor to the housing.
Step 5

Repair step

  • Lift the old motor out of the housing.
  • Position the replacement motor in its place.
  • Confirm the replacement motor is rated for 12V DC before installing it.
Step 6

Repair step

  • Reinstall the two Phillips #00 screws to secure the new motor to the housing.
Step 7

Repair step

  • Flip the housing back over, then press the fan blade assembly onto the motor shaft until it sits flush.
  • Align the flat side of the motor shaft with the flat side of the fan blade hub before pressing the blades into place.
Step 8

Repair step

  • Reinstall the five Phillips #1 screws to secure the fan housing back onto the range hood frame.
  • Restore power at the breaker or fuse panel, then test the fan at each switch speed to confirm it runs properly.