Before you begin

To complete this guide, you will need to disassemble your device and use a soldering iron to replace the jack.

Step 1

Repair step

  • Turn the device upside down so that the three rubber pads are facing up.
Step 2

Repair step

  • Use a heat gun (set to low) to apply heat to one of the rubber pads until you can easily remove the pad. This step takes around 5-7 minutes.
Step 3

Repair step

  • Remove the heated rubber pad with a plastic opening tool.
  • Repeat steps 2 and 3 for the two remaining rubber pads.
Step 4

Repair step

  • Remove the six 1cm T-10 torx screws on the bottom of the device (found under the rubber pads) using a T-10 Torx screwdriver.
Step 5

Repair step

  • Open the device along its seam.
  • Be careful when separating the device because there are wires connecting the two seperate halves.
Step 6

Repair step

  • Disconnect the ribbon cable connector from the top half of the device by pulling outward and parallel to the connecting pins.
Step 7

Repair step

  • Locate and disconnect the two molex connectors found on either side of the ribbon cable connector on the bottom half of the device.
Step 8

Repair step

  • Remove the three 1 cm T-10 Torx screws.
Step 9

Repair step

  • Carefully press out the white base tube and push up on the circuit board.
  • Note that there is a small wire connecting the circuit board to the base.
Step 10

Repair step

  • Pull the white wire out of the hot glue.
Step 11

Repair step

  • Unbolt the heatsink with a 5.5-mm socket and a Phillips PH1 screwdriver.
  • Remove the heat sink; it should detach from the bottom of the device.
Step 12

Repair step

  • Remove the T-10 torx screw on the bottom of the device that attaches the base tube to the circuit board.
  • Turn the device so that the base tube is on top.
  • Remove the base tube by pulling up.
  • May need to cut the rubber adhesive between the base tube to the circuit board.
Step 13

Repair step

  • Turn the device upside down.
  • Desolder the back lead for the auxiliary port that is circled.
  • Heat the lead until the solder melts.
  • Remove the solder with the solder pump.
  • For help with soldering view the iFixit soldering guide
Step 14

Repair step

  • Repeat step 13 for the other two leads.
Step 15

Repair step

  • Turn your device right-side up.
  • Remove the auxiliary jack.