MANTRA NISEKO cooling fan, cooling fan motor not working, driver failure.

Attributed iFixit repair guide for Lámpara - Ventilador MANTRA - NISEKO.

iFixit Library Lámpara - Ventilador MANTRA - NISEKO Moderate 30 minutes Guide 228174
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Step 1

MANTRA NISEKO cooling fan

  • The MANTRA NISEKO cooling fan stopped working without showing any symptoms; the LED light was working correctly.
  • The first thing I tested to rule out any issues was changing the remote control batteries.
  • The second thing I checked to rule out any issues was re-pairing the cooling fan with the remote. Turn off the cooling fan using the wall switch, wait a few seconds, then turn it back on using the switch. The light will turn on, and within 30 seconds, you must press and hold the center button on the remote for 6 seconds, as indicated in the instructions.
  • The light will flash intermittently to acknowledge that it has been paired with the remote. If the cooling fan still does not respond after doing this, it is time to check the driver connections by removing the ceiling canopy.
  • Manufacturer's video on remote pairing…
Step 2

Repair step

  • Identifying the connectors, the assembly with the yellow/gray cable (light fixture). Disconnect the male and female parts of the connector with the red/black cable (cooling fan), reconnect them to rule out a failure, and test the cooling fan.
  • Testing again, the cooling fan remains the same; I disassembled the driver to check inside, observing that all components are sealed in "anti-moisture" and "anti-repair" resin (even if the manufacturers do not want to acknowledge the latter).
Step 3

Repair step

  • With a multimeter, we can check a couple of parameters: Check with the multimeter on the DC voltage scale, close to 50 V, that when the cooling fan is supposed to be running, we should have DC voltage (up to 24 V) at the output connector; "there is NO output voltage".
  • Video explaining the check.
Step 4

Repair step

  • Checking the motor winding to rule out motor issues; it is okay, both coils measure approx 6 ohms.
  • Manufacturer's video on the installation.
Step 5

Repair step

  • At this point, if the cooling fan is less than 3 years old (warranty in Spain), you should go to the store where you bought it so they can claim a replacement for the driver from the importer.
  • For cooling fans out of warranty, you must request a spare part directly from the importer through their website.
  • Contact the store where it was sold; under warranty, they requested a replacement driver, and upon reinstalling it, they confirmed that this was the problem.