FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Cricut Explore 3 (CXPL203) disassembly

This guide demonstrates the non-destructive...

iFixit Library Cricut Explore 3 Moderate 30 minutes Guide 228209
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide demonstrates the non-destructive disassembly of the Cricut Explore 3 (CXPL203). The device has several hidden screws that make non-destructive opening difficult. Repaired at Repair Café Markgröningen on August 8th 2026

Step 1

Remove bottom screws

  • Remove rubber pads, there are screws underneath.
  • Remove the 11 screws on the bottom. Picture shows the different lengths to their corresponding holes.
Step 2

Remove flat cable cover

  • push tool sled into the right housing side. One of the tools needs to be lifted in order to push it over the limiter
  • Lift cable cover on the left and pull it out. This step requires some force.
  • Remove cover from device by pulling it towards you on the left, carefully pull the right side from behind the sled
Step 3

Remove side covers

  • Release the 6 marked Philips screws. Two of them are hidden behind the cable cover.
  • Side covers can now be removed. The right one has a cable that needs to be unplugged from the main board.
  • Unplug the cable as straight as possible, as the pins in the connector might otherwise bend.
Step 4

Remove screws and connectors from mechanical unit

  • Remove connectors and tapes from the wire harness. Repeat on the opposite side.
  • Undo the screws holding the mechanical unit to the bottom. Repeat on the opposite side.
  • Marked screw holds the grounding wire, don't forget during reassembly.
  • Undo screw on the right side. Apart from the Philips drive, it also has a hex head and can be undone with a small spanner without needing to cut through the plastic.
  • DO NOT lift mechanical unit from the device, remove cables first in the following steps. Hazard of damaging the cables.
Step 5

Remove cables to mechanical unit

  • Pry up mechanical unit about 1 cm with a plastic opening tool.
  • Unlock ZIF socket, remove flat flex cable
  • Don't forget to lock socket during reassembly, e.g. using the spudger
  • Pry up mechanical unit further.
  • Release the two connectors for the light sensors, pay attention to connector colors during reassembly.
Step 6

Mainboard

  • Mainboard can now be removed by undoing the marked screws. Don't forget grounding harness during reassembly
  • The marked hole holds no screw