Repair step
- I have dedicated several documents to this coffee machine. If there is AC voltage at the LINE and NEUTRAL input (green arrows) but the machine does not turn on, we will have already ruled out that the 2 thermal fuses on the boiler are in good condition, otherwise we would not have voltage at the input.
- These are the components that can cause problems on this electronic PCB.
- 1st Large rectangular capacitor, blue, red arrow, is the one I have found faulty on several occasions. The yellow arrow indicates the capacitor's self-discharge resistance when the machine is off; this does not usually fail and is only a safety measure.
- 2nd Orange arrow, input fuse-function resistance; on this PCB, on the other side, we also have a thin copper trace that performs the function of a fuse; check the other side as you may have a blown trace.