Repair step

  • I have dedicated several documents to this coffee machine. If there is AC voltage at the LINE and NEUTRAL input (green arrows) but the machine does not turn on, we will have already ruled out that the 2 thermal fuses on the boiler are in good condition, otherwise we would not have voltage at the input.
  • These are the components that can cause problems on this electronic PCB.
  • 1st Large rectangular capacitor, blue, red arrow, is the one I have found faulty on several occasions. The yellow arrow indicates the capacitor's self-discharge resistance when the machine is off; this does not usually fail and is only a safety measure.
  • 2nd Orange arrow, input fuse-function resistance; on this PCB, on the other side, we also have a thin copper trace that performs the function of a fuse; check the other side as you may have a blown trace.
Step 2

Repair step

  • 3rd This is not very likely since the circuit board is well designed, but we may find that the power triac transistor (purple arrow) for the boiler is short-circuited and has burned the copper trace I mentioned in the previous step.
  • 4th Capacitor problem: I have marked the ones that can cause problems. I have not encountered them as faulty on any occasion, but it does not hurt to take a look at them.
Step 3

Repair step

  • ATTENTION The coffee maker should be unplugged from the power outlet.
  • Before performing the check or measurement of the large rectangular capacitor, we must discharge it by bridging its terminals; otherwise, we risk burning out the CAPACITANCE METER if we are using such measuring equipment. A residual voltage in the capacitor can cause certain and irreparable damage to our measuring equipment.
  • In another document, I cover the replacement of the component. Cafetera Nespresso Delonghi EN 95.R