Guide overview

Before you begin

The Jabra Evolve 75 headset's microphone cable runs through the PCB and rubs against it when the microphone is swiveled up and down. Eventually, the cable breaks and the microphone stops working properly. At first, it may work intermittently, but later the connection is completely severed. Here, I describe how to repair the cable.

Step 1

Remove the speaker

  • Remove the T4 Torx screw that secures the right speaker to the frame (Image 1).
  • Push down on the speaker and remove it with a slight twisting motion. The pivot point is the end of the speaker opposite the screw. (Image 2)
  • This battery replacement guide contains a good video on how to remove the speakers: https://de.ifixit.com/Anleitung/Jabra+Ev...
Step 2

Watch out for the speaker cable!

  • From now on, take care throughout the entire repair that no excessive load is placed on the speaker cables. The cables are soldered on and the solder pads are covered with black adhesive. These cables are now the only connection to the PCB and are not intended for mechanical stress. (Image 1)
  • It is best to place the speaker on the work surface while working. I rotated it 180 degrees to the side so that the PCB is freely accessible (Image 2)
  • If you need to pry up or turn over the headset, always support the weight of the headphones. Do not let it dangle by the cable.
Step 3

Remove the button pad

  • Remove the 3 "raised" screws using a T6 Torx screwdriver. The other 4 screws in the recesses secure the PCB to the frame and can remain in place. (Image 1)
  • Remove the screws, as they may otherwise fall out later and potentially get lost. Now remove the button pad. (Image 2)
Step 4

Removing the internal plastic cover

  • The plastic cover covering the underside of the PCB is glued in place and can be carefully lifted with a spudger. If you use a metal spudger, take care not to scratch the PCB. (Image 1)
  • The glue has a rubbery consistency and does not break suddenly; it must be separated slowly and carefully. (Image 2)
  • Once you have loosened the glue, take a moment to look at the following 4 potential problem areas more closely before you continue: (Image 3)
  • 1: sleep/wake button - can fall out, although it usually stays in place. If it does fall out, make sure to insert it in the CORRECT (off) position; 2: ANC microphone - watch the cable!; 3: mute switch - easily falls out, take care; 4: earpiece mounting bracket - usually falls out, so it is best to remove it beforehand (Image 3)
  • Now remove the plastic cover from the PCB. Pay special attention to the ANC microphone and its cable. It should remain in place, but sometimes gets caught on the cover. The speaker cables go through a hole in the cover, so you cannot remove it completely. Rotate it to the side by 180 degrees (see step 2)
Step 5

damaged cable

  • under the cover, the PCB becomes visible. you can see the damaged cable (image 2 - not always this clearly, but this is usually the failure point) and the soldering points that are covered in a black glue.
  • for the first repair attempt, in which image 1 was taken, I mistakenly removed the 4 recessed screws (see step 3), that is why the PCB is loose in the image. if you leave the screws installed, the PCB will also remain in position in the housing.
Step 6

remove cable

  • Do NOT cut the cable yet!
  • Remove the black rubbery glue on the solder pads. A fibre glass eraser works best (image 1)
  • The glue will melt or combust when you heat the solder up with the iron. However, try and remove as much of the glue as possible beforehand.
  • Now de-solder the cable and clean the solder pads with a solder wick. (image 2)
Step 7

prepare cable for repair

  • Before you flip the headset around, remember to support the weight of the speaker when doing so; do not let the speaker simply dangle.
  • The original cable is a coax cable with no real physical separation between the inner and outer strand. The inner strands are covered in an insulating paint. (Image 1)
  • Cut the cable exactly at the damage point. Cut it in a way that as much cable length as possible remains for the microphone rotation function.
  • Remove the insulation from the cable.
  • Separate the cable strands from each other. Make sure the inner strands (recognizable by the red insulating paint) are really 100% separated from the outer ones (copper color). (Image 2)
Step 8

solder in new cable

  • Unfortunately, I am missing a few good pictures at this point in the repair. If you have good pictures, feel free to contact me.
  • there is a YT video (not by me!) outlining these steps very well: https://www.youtube.com/watch?v=OcYFOJ0A...
  • If you can find a cable with more cross section, that you can fit through the hole in the PCB - use that. The only cable I could find that fit through the PCB was a 2x 0,04mm² cable. It works fine, I would just have liked to use a thicker one. The next cable size I could find was 2x0,1mm² and it was already too thick for the hole.
  • Feed the new cable through the hole in the PCB and strip both strands approximately 8mm.
  • Solder the cable to the pads. One of the points (the lower one in the picture above) is marked with M- on the PCB - this is the negative pole so it gets the black cable.
  • Cut the cable approximately 5cm behind the hole in the PCB and remove the insulation from both strands ~8mm.
Step 9

glue on additional PCB, solder wires

  • Cut a 2x1 piece off the perforated PCB and glue it with hot glue to the chip on the front of the PCB (see green rectangle in the image)
  • Solder the two leads of the new cable (which passes through the PCB) to the two solder points on the perforated PCB.
  • Note: In the picture, the black cable is not properly soldered yet. It should be completely surrounded by solder. I unfortunately did not take another photo of the final state.
  • Now solder in the microphone cable. Read the following steps first:
  • The outer lead is just bare copper and can be soldered to the PCB together with the black lead of the new cable (this is the negative line).
  • Due to the insulating lacquer on the inner positive lead, you must ensure that the face (the end) of the wires is inside the solder. If the end is sticking out and only the insulated strands are surrounded by solder, you will not have a connection.
  • Alternatively, you can remove the insulating lacquer if you know how. Unfortunately, I was unable to remove it with the tools I had available.
  • Test the microphone now before reassembling everything. If it does not work, re-solder the points, especially the positive cable.
Step 10

Reassembly

  • If the microphone is working, you can turn the headset off again and reassemble. Watch out for the following potential hurdles:
  • picture one: when you put the plastic cover back in place, make sure that the 4 marked items are all where they belong and that the ANC cable is not under any strain or pinched, etc. The "mounting bracket" (number 4) must be put on its pin, before you put the plastic cover back in position.
  • picture 2: remember to reinstall the button pad and tighten the screws. Read the next step first.
  • picture 3: BEFORE you put in the button pad, make sure that the microphone cable is in its correct position. The button pad has in total 6 "arms" that touch the PCB (see those locations marked with purple circles) and when you swivel down the microphone, it needs some free slack.
  • Therefore, make sure the cable is not caught or damaged by any of the 6 arms and is routed exactly where it is in the picture, otherwise the microphone will not swivel down properly.