Replace Bestway LAY-Z-SPA S100101 water pump shaft

This guide covers a broken ceramic shaft in the...

iFixit Library Poolheizung Bestway Moderate 3 hours Guide 239070
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide covers a broken ceramic shaft in the water pump of a Bestway LAY-Z-SPA S100101 pump unit. The model name can be found on the rating plate of the pictured device. In the case of the described defect, E02 appeared and the pump was unusually loud. E02 indicates missing or insufficient water flow and does not in itself prove a broken shaft. A repair report by Dan Bemowski in English describes multiple causes and different impeller versions.

Step 1

Opening the pump

  • Unplug the pump unit before opening it. Do not work on the open unit while it is connected to the power supply.
  • Disconnect the unit from the water circuit only once the connections have been sealed or the water has been drained in a controlled manner according to the device manual. Keep the electrical area dry.
  • Open the pump unit housing to access the water pump.
  • The first photo shows the unit already opened. The following photos show the opened pump cover and the impeller.
Step 2

Remove the broken axle

  • Remove the fragments of the ceramic axle from the impeller and the bearing seats.
  • Keep the rubber bearings. The photo shows a bearing next to the fragments.
  • Insert a replacement axle that matches the length and diameter. Compare it with the original axle; the model name S100101 alone does not determine the axle dimensions.
Step 3

Assemble the device

  • Set the rubber mounts into their original slots and check that the impeller can move freely before closing.
  • Insert the existing seals correctly and close the pump cover and housing without pinching any cables.
  • Check the restored water circuit for leaks first with the device unplugged. Do not power on until the electrical area is dry and the housing is closed.