Olympus OM-D E-M5 Shutter Motor Repair

This guide addresses a specific issue with the...

iFixit Library Olympus OM-D E-M5 Difficult 3 hours Guide 241867
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide addresses a specific issue with the Olympus OM-D E-M5, where the EVF and rear display remain black upon powering on, the shutter curtain remains closed, yet the menu screen is visible via HDMI on an external monitor. This behavior is typically caused by a faulty shutter unit drive motor, rather than a failure of the main board. This procedure involves a near-complete teardown of the device to remove the malfunctioning shutter motor. In this instance, normal functionality was restored by transplanting the internal brushes from a similarly sized motor sourced from another camera (Nikon COOLPIX S8200). Required Skills • Precision soldering, the disassembly/reassembly of micro-mechanical parts, and a peculiar personality that enjoys tedious tasks. Tools Required • Phillips screwdriver (Size #00 recommended) • Tweezers • Soldering iron and desoldering pump • Craft knife and spatula (for removing the front rubber) • Screw mat (e.g., FixMat or a commercial magnetic sheet) • External power supply (a variable voltage unit is recommended for motor testing; having a built-in ammeter is even better) Warning • This guide is based on memory and photographs from that time, so the content may be incomplete; I would appreciate it if you could point out any mistakes. • Repairs carry inherent risks, including the potential for injury, burns, smoke or fire hazards, and the possibility that disassembly may worsen the device's condition. Proceed at your own risk.

Step 1

Step 1: Removing external parts and the bottom panel

  • Before beginning, remove the battery, SD card, lens, and EVF eyecup.
  • Remove the battery cover from the device.
  • Remove the seven screws on the bottom of the camera, then remove the bottom panel.
  • Remove the two silver screws and the one black door-retaining screw on the underside of the bottom panel.
Step 2

Step 2: Removing the exterior and front apron screws

  • Open the terminal cover (rubber door) on the left side when viewed from the back, and remove the one internal screw and one bottom screw.
  • Remove the two screws at the top of the viewfinder, and the two top screws behind the rear LCD located around the bottom left and right of the viewfinder.
  • Carefully peel off the two rubber sections on the left and right of the front apron using a spudger or similar tool.
  • Remove the three screws around the front apron (top left, top right, and bottom), then remove the apron section.
  • Remove the two silver screws and two black screws located under the apron, as well as the one silver screw on the top left when viewed from the front.
  • Remove the two black set screws to remove the silver tripod mount screw receptacle on the bottom.
Step 3

Step 3: Removing the back panel and main board

  • Carefully pull the back panel unit away from the main body and disconnect the FFC (flat flexible cable) that is connected.
  • Use a solder sucker or similar tool to remove all solder from the battery box wiring and the various other wiring points.
  • Disconnect the remaining FFC, remove the four screws, and pull out the main board assembly. *Note: In the photo, the top cover is removed first. Feel free to adjust the order as you prefer.
  • Caution: A metal bracket is held in place by the bottom-left screw; be careful not to lose it.
Step 4

Step 4: Removing the Top Plate and IS (Image Stabilization) Unit

  • Once the board is removed, remove the one screw on the upper left and the one on the upper right as viewed from the back, and remove the camera's top plate.
  • Remove the three screws securing the IS (Image Stabilization) unit and remove the entire unit.
  • Hidden screw warning: One of the screws is hidden about 1 cm deep inside a black plastic cap.
  • Loss prevention warning: There are alignment spacers (shims) between the body and the IS unit on all three screws. Record and store exactly where each spacer was located, as they are crucial for maintaining proper optical axis alignment during reassembly. The IS unit contains powerful magnets; be careful not to let screws or other metallic items get pulled into it.
  • The IS unit contains a high-end type driven by an electromagnet. It is normal for the image sensor to move slightly within the unit. If it does not move at all, it may be jammed by foreign debris, or the unit may have been dislocated due to impact—such as from a drop—causing the gap to narrow and trap the image sensor. (This is like the thick metal plate spacers shifting and turning a rectangle into a parallelogram; you can force it back into the normal position.)
  • Incidentally, if the protective circuit is triggered due to the image sensor being trapped, it appears the symptoms are that the power turns on but immediately turns off, or, in ART mode, it stays on a little longer but still shuts down.
Step 5

Step 5: Separating the shutter unit

  • Remove the "two external screws" on the left side when viewed from the back, then remove the metal plate and speaker located on the left side of the shutter unit.
  • Remove the copper washer and one screw on the right side of the shutter unit, along with one thick screw on the left side (there is another screw hole, but there was no screw attached to this unit).
  • Once the securing screws are removed, carefully pull the shutter unit out of the device.
Step 6

Step 6: Motor unit full teardown

  • Remove the two screws on the front of the shutter and separate the motor unit (housing).
  • Disconnect the solder joints where the FFC cable is connected and the solder at the motor electrode, then remove the two screws to take off the FFC retaining plate.
  • Remove the larger silver plate to reveal the internal gears.
  • Tips: Once only the motor and mechanism remain, you can perform a simple operation check. Since you can infer the rotation direction by the shape of the cam, apply approximately 3V to the motor from an external power supply to check if it rotates in the forward direction.
Step 7

Step 7: Gear and Motor Removal

  • Perform removal of the two screws on the gear retaining plate, then carefully use tweezers to remove the cam and the two internal gears.
  • Check: At this stage, use a loupe or similar tool to visually inspect each gear for cracks or chips (the unit used here had no cracks). Make sure to carefully note the layout of each gear and the cam so you do not have trouble during reassembly.
  • Note: Micro-cracks in the pinion gear are fairly common; when torque is applied, the gear may slip and spin freely, preventing the shutter curtain from operating normally. While it seems this can be addressed to some extent by applying a tiny amount of adhesive into the shaft area, it is better to replace it if possible.
  • The motor has polarity. To prevent it from being reversed during reinstallation, it is helpful to use markings on the housing and the motor body to mistake-proof the process.
  • By performing removal of the two motor retaining screws, you can completely pull the small DC motor—the source of the issue—out of the housing.
Step 8

Step 8. Motor inspection and repair or replacement

  • Symptom confirmation: Apply approximately 3V from a test power supply to the motor and check if it rotates properly. The faulty motor I removed was in a state of complete internal failure; despite an abnormal current of 1A flowing in the forward direction, it only rotated at an extremely low speed, and in the reverse direction, it would not start without being given a manual initial spin.
  • It would have been ideal to obtain an identical motor, but unfortunately, I could not. I attempted a Teardown by removing the motor's crimps to perform repairs. The disassembled motor had bent and damaged brushes, and was experiencing a short circuit inside the motor. Therefore, I transplanted only the brushes from a donor motor, and reassembled it after cleaning and applying a trace amount of light silicone oil to the metal.
  • Tips: Although the electrode from the internal brush is originally a single plate, it was a completely different shape than the donor motor, so I cut and used only the brush portion. I intentionally did not solder the brushes to the electrode, but instead held them in place by precisely fitting them into the internal structure; this resulted in good operation.
  • ※No photo available due to data loss
Step 9

Step 9. Reassembly and Function Check

  • Notes for reassembly
  • Follow these steps in reverse order to reassemble the device. When replacing the image stabilization unit, ensure that all three optical axis adjustment spacers are correctly positioned in their original screw holes before tightening. The magnets on the image stabilization unit are powerful, which made reassembly difficult as they pulled on the screws and washers. While you can slide the washers in from the side for two of the three screws, this is difficult for the hidden screw, so I used a small amount of threadlocker to hold it in place. Since the screws are also pulled by the magnets, I used a small amount of superglue to lightly hold them to the screwdriver.
  • When reinstalling the logic board, I forgot to solder the battery box, which prevented the device from powering on at all. This is a step that is surprisingly easy to forget, so please be careful.
  • Once the rear panel is attached, perform a quick overall check and verify that the device powers on.