Sony SRF-R356 Unstable Operation and Power Failure Repair

This guide covers symptoms in the Sony SRF-R356...

iFixit Library Sony Radio SRF-R356 Difficult 2 days Guide 245084
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This guide covers symptoms in the Sony SRF-R356 pocket radio where it fails to power on even with fresh batteries, becomes unresponsive even when it does power on, or fails to power off. Although I replaced several obvious chip capacitors and the supercapacitor, the symptoms only improved slightly and were not fully resolved. I performed a thorough analysis again, traced the issue to the backup power circuit on the board, and successfully resolved the problem by replacing a chip diode. I am creating this guide as a reference for this type of repair. Required Skills • Precision soldering, disassembly and assembly of minute parts, and the peculiar personality to enjoy the analytical work required for difficult repairs. Required Tools • Precision Phillips screwdriver (size #00 recommended) • Precision tweezers • Soldering iron and solder sucker, etc. • Multimeter (an oscilloscope is even better) • Freeze spray • External power supply (to replace batteries) Caution • This guide is based on my memory and photos from the time of the repair, so it may be incomplete. I would appreciate it if you could point out any errors. • Repairs carry risks, including the possibility of injury, burns, smoke or fire, and the possibility that the device ends up in worse condition after disassembly. Proceed at your own risk if you choose to attempt this.

Step 1

Teardown and logic board removal

  • Since the structure is simple, I will omit detailed instructions. Remove the four external screws and remove the rear housing. Please note that there are also screws inside the earphone storage compartment and under the battery cover.
  • The earphones are attached to the rear housing, and I believe a FFC was connected to the logic board; please be careful not to tear it when performing removal.
  • The speaker is attached to the front housing and is connected to the logic board via solder, so perform removal.
  • Furthermore, by removing several screws securing the logic board to the housing, you can perform removal of the logic board.
  • ※A supercapacitor for clock backup is attached to the logic board. I thought this was the culprit and replaced it first, but there was no change in the symptoms.
  • Inside the shield plate, the LCD display is attached to the logic board via FFC. Remove the shield plate, release the lock to perform removal of the FFC, and temporarily remove the LCD display.
  • Furthermore, by using a soldering iron to perform removal of the shield plate under the LCD display, you will be able to access the backup circuit group.
Step 2

Narrowing down the cause

  • Reconnect the liquid crystal board that was removed, apply 1.5V to the board, and operate the power switch to check its behavior.
  • Use a coolant spray to cool each part of the board one by one, and narrow down the point where the power fails to turn on when cooled.
  • If the behavior does not change when cooled, the symptom may occur when warmed with a hair dryer. If you have a hot air station, please apply spot heating lightly and observe the behavior.
  • After a patient investigation, it was found that when the standby circuit inside the shield is cooled, the power becomes extremely difficult to turn on or becomes unstable.
  • ※The photo shows the state after various parts have already been removed.
Step 3

Power Circuit Analysis and Identifying the Faulty Location

  • It might be a little difficult to see, but the left side of the photo shows the voltage in standby mode, and the red text on the right shows the voltage when it is turned ON.
  • Two power ICs are visible in the top and bottom of the photo; identifying these ICs would make the analysis easier. Based on the surrounding circuits and the shape of the ICs, I compared them with datasheets for power ICs from various manufacturers, but I could not find a match. My guess is that the bottom one is a Torex XCL110 (mark 233) and the top one is a custom part (mark 130) with the left and right pin configurations reversed. (If anyone knows the correct identity, please let me know privately.)
  • Now that I understand the faulty circuit, I will patiently measure the voltage with a multimeter while referencing the power IC datasheet and the reference circuit, recording the changes between standby mode and when it is turned ON. *In reality, I performed the voltage measurements while checking for noise with an oscilloscope, but I believe it can also be analyzed simply using just a multimeter.
  • After careful investigation, I was able to infer that the voltage applied to the capacitor circled in red on the right is part of the standby system. Furthermore, it became clear that the voltage during startup was unstable and would not rise fully, causing the startup failure.
  • Thinking I had identified the cause, I removed the chip capacitor and tried replacing it. After measuring it with a capacitance meter, I found it to be a 12uF high-capacity chip ceramic capacitor, so I replaced it with a new capacitor of a similar capacity, but unfortunately, the symptoms did not subside.
Step 4

Identifying and Replacing the Faulty Component

  • At this stage, I suspected the ultra-miniature diode near the capacitor. Upon removal, it appeared to be degraded and cracked, and it snapped in two.
  • Referring to the power IC datasheet and other resources, I replaced the diode with a slightly larger one: 【RB520S30T1G】. The specs are DIODE SCHOTTKY 30V 200MA SOD523.
  • There is an identical diode in the same location on the lower circuit, so I replaced it as a preventive measure.
  • ※Because the diode was too large, I used 0.2mm polyurethane wire for part of the wiring.
  • After replacing the two diodes, the voltage stabilized, and the device began to boot and operate consistently.
  • I have been using the device after reassembling the housing, and so far the symptoms have not recurred and it seems stable.