Guide overview

Before you begin

Blank Indoor Thermostat or No Power to Thermostat The Gremlin: (it's actually working properly) Indoor thermostats controlling modern central AC and heating units are powered by either a small transformer near the AC attic air handler or by the AC unit itself. If the thermostat was working fine and then suddenly lost that power, it may be a simple fix: especially in the spring. The thermostat may go dark and then start working again after a while only to go dark again. Backup batteries on a thermostat are usually just to save configuration; they don't power the functions or display of the thermostat. The Horror: (it's not really that scary) In the spring, it's common for high humidity to require the AC unit to remove significantly more moisture from the air than is required in winter. The drain for that moisture may become overwhelmed or clogged by that higher volume of water. A simple float switch is installed in that attic AC drainpipe that opens the circuit powering the thermostat when the drain backs up. It's a simple solution to a common problem that can save you big bux by stopping the AC before the emergency drain overflows resulting in a floor covered in wet ceiling sheetrock. Tip: Search AC Condensate Switch on Amazon to get an idea what the float switch looks like. There are several versions. The Hero: (that would be YOU) Locate the (usually PVC) drainpipe for the AC air handler usually placed immediately below the air filter. There should be a small box made into the drain with two wires entering the box. You should be able to release the door on that box to access the float switch. Usually, after some time of nonuse, the water will slowly drain and the float switch will allow power to the thermostat until it fills again. Remove as much of the water as possible. (just removing the excess water will make your thermostat function again so don't jump when the AC starts) and Find a way to blow air into the drain pipe going downward; this will often push the clog through and provides a temporary fix. You can also use a small amount of drain cleaner to clear the pipe.. To stop the clog from returning, pour vinegar slowly into the drain. This will kill and inhibit the algae that created the clog. Whenever you replace the air filter, pour 2-4 ounces of vinegar down the drain to keep it working perfectly.

The iFixit procedure is temporarily unavailable through the API.

You can still open the attributed original source safely.

Open the authorised source