Spy Net Ultra Vision Goggles Infrared Lights Replacement

This device features two sets of infrared...

iFixit Library Spy Net Ultra Vision Goggles Moderate 15 - 30 minutes Guide 30587
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This device features two sets of infrared lights. The set on the left side is for long range, while the set on the right is for short range. This guide shows the steps for replacing the long-range set, but the process is the same for the short-range set as well. Before you begin, be sure to take a look at the Device Troubleshooting Page to verify that the infrared lights are really faulty.

Step 1

Open the Device

  • Remove the six silver 11.4 mm Phillips #0 screws that hold the device shell in place.
  • Pry open the shell using the plastic opening tools if necessary. To do this, locate the groves running along the side of the entire device and wedge it open.
Step 2

Remove the Infrared Lights

  • Find the infrared light assemblies, which are located at the front end of the device on either side of the lens.
  • The process is the same regardless of which light you are replacing.
  • Lift the light assembly away from the rest of the device.
Step 3

Open the Light Assembly

  • Use the plastic opening tools to pry open the light assembly.
Step 4

Disconnect the Lights

  • Use the soldering iron and desoldering braid to de-solder the wires from the lights.