The purpose of this guide is to replace the eyepiece (plastic rectangular piece around the viewfinder) of a Nikon Coolpix P90 if it is loose, broken, or lost. In steps 3-4, 6-7, and 9, there are three data connection ribbons which need to be carefully removed before the repair can continue. Failure to remove these ribbons properly will result in them becoming damaged or ripped, thereby permanently damaging your camera. So, please be careful and go slowly during this repair. Take a look at this guide on Recognizing and Disconnecting Cable Connectors for helpful information on safely disconnecting the connectors in this guide. Before you begin this repair, be sure that your camera is off, the battery is removed, and it is disconnected from the charger.

Step 1

Camera Base

  • Use your finger to push the latch of the compartment door to the center of the camera body, per image 1.
  • Push the door open, and remove the existing battery with your fingers, per images 2-3.
Step 2

Eyepiece

  • Use a Phillips #000 Precision Screwdriver for all of the following steps.
  • On the bottom side of the camera, remove two 4.5 mm screws holding the bottom case in place.
  • On the right side of the camera, remove two 4.5 mm screws.
  • On the right side of the camera, remove the single 4.5 mm screw underneath the A/V flap.
  • On the top of the camera, remove the 4.0 mm screw on the left-side wrist strap loop.
Step 3

Repair step

  • Lift up the LCD screen to reveal the two screws.
  • Use a Phillips #000 screwdriver to remove the two 3.0 mm screws that hold the arm in place.
Step 4

Repair step

  • Carefully lift up the back cover from the rear side of the camera.
  • Do NOT completely remove the back cover from the camera yet. There is a data transfer ribbon connecting the LCD screen to the motherboard.
Step 5

Repair step

  • Use a spudger or a clean fingernail to flip up the locking flap on the ZIF connector. This is the unlocked position.
  • Be careful when releasing the safety latch because it is fragile and may break easily.
  • Use tweezers or your fingers to gently pull the cable out of its socket.
  • If the cable has a pull tab, use it to grip the cable. You may damage the cable by gripping it directly.
  • To reconnect, make sure the locking flap is flipped up and gently reinsert the cable. Then, flip the locking flap down to secure the cable. The cable should slide into the socket with little to no force. If you're having trouble, remove it, check that the flap is fully unlocked, and try again.
  • It is now safe to completely remove the back cover from the camera.
Step 6

Repair step

  • Use a Phillips #000 screwdriver for all of the following steps.
  • On the back side of the camera, remove the seven 4.0 mm screws that connect the metal plate to the motherboard.
  • On the top side or the camera, remove the three 4.0 mm screws that connect the metal hinges to the camera body.
Step 7

Repair step

  • Carefully lift the metal backing from the motherboard.
  • Do NOT completely remove the metal backing yet. There is a data transfer ribbon connecting the metal backing to the motherboard.
Step 8

Repair step

  • Use a spudger or a clean fingernail to flip up the locking flap on the ZIF connector. This is the unlocked position.
  • Be careful when releasing the safety latch because it is fragile and may break easily.
  • Use tweezers or your fingers to gently pull the cable out of its socket.
  • If the cable has a pull tab, use it to grip the cable. You may damage the cable by gripping it directly.
  • To reconnect, make sure the locking flap is flipped up and gently reinsert the cable. Then, flip the locking flap down to secure the cable. The cable should slide into the socket with little to no force. If you're having trouble, remove it, check that the flap is fully unlocked, and try again.
  • Remove the metal bracket from the camera.
Step 9

Repair step

  • Use a Phillips #000 screwdriver to remove the 3.0 mm screw that holds the eyepiece in place.
Step 10

Repair step

  • Do NOT completely remove the eyepiece yet. There is a data transfer ribbon connecting the eyepiece to the motherboard.
  • Use a plastic opening tool or spudger, carefully unlock the safety latch that holds the eyepiece data transfer ribbon in place.
  • Slide the ribbon out from its socket.
Step 11

Repair step

  • Gently pull the eyepiece from the camera to remove it.