FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

MacBook Air 13" Late 2010 Fan Replacement

Use this guide to replace a burned-out fan.

iFixit Library MacBook Air 13" Late 2010 Moderate 10 - 30 minutes Guide 4508
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Use this guide to replace a burned-out fan.

Step 1

Repair step

  • Before proceeding, power off the device, close the lid and lay it on a soft surface top-side down.
  • Remove the following ten screws:
  • Two 9 mm 5-point Pentalobe screws
  • Eight 2.6 mm 5-point Pentalobe screws
  • The special screwdriver needed to remove the eight 5-point Pentalobe screws can be found here.
Step 2

Repair step

  • Wedge your fingers between the display and the lower case and pull upward to pop the lower case off the Air.
  • Remove the lower case and set it aside.
Step 3

Repair step

  • For precautionary purposes, we advise that you disconnect the battery connector from the logic board to avoid any electrical discharge. This step is optional and is not required.
  • Grab the clear plastic pull tab attached to the battery connector and pull it toward the front edge of the Air to disconnect the battery from the logic board.
  • Do not lift upward on the connector as you disconnect it.
Step 4

Repair step

  • Use the flat end of a spudger to pry the I/O board cable connector upward out of its socket on the I/O board.
Step 5

Repair step

  • The following connector has an especially deep socket. Use care when disconnecting it.
  • Carefully peel the I/O board cable from the top of the fan.
  • While gently pulling the I/O board cable upward near its connection to the logic board, use the tip of a spudger to pry upward on alternating sides of the connector to help "walk" it out of its socket.
  • Remove the I/O board cable.
Step 6

Repair step

  • Use the tip of a spudger to carefully flip up the retaining flap on the fan cable ZIF socket.
  • Be sure you are prying up on the hinged retaining flap, not the socket itself.
Step 7

Repair step

  • Peel the rubber gasket off the adhesive on the top of the fan.
Step 8

Repair step

  • Remove the following three screws securing the fan to the upper case:
  • One 3.6 mm T5 Torx screw
  • One 2.7 mm T5 Torx screw
  • One 3.6 mm T5 Torx screw with a short head
Step 9

Repair step

  • Lift the fan out of the upper case and carefully pull the fan ribbon cable out of its socket as you remove it from the Air.