FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

scala rider Q2 multiSet battery replacement

This bike-to-bike intercom system was given to...

iFixit Library Scala Rider Q2 MultiSet Moderate 20 minutes Guide 61081
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

This bike-to-bike intercom system was given to me by a friend for repair. He is an avid bike rider and purchased this set a while ago but did not have time to ever use it. Once he did try to charge it it would not take a charge. I assumed that it was the batteries since they have never been charged. They may have been depleted below the threshold of where they would accept a charge. When he called the cardo support number he was told that "There is no out of warranty service for scala rider batteries." He would need to purchase a new scala rider headset in this case. Really? Lets check this myth about the "not user serviceable" battery.

Step 1

Repair step

  • scala rider Q2 bike-to-bike intercom. Retail price $379.99 and never used.
  • Individual unit with carrying pouch
  • Back of the bluetooth intercom device
Step 2

Repair step

  • The unit is held together by 4 T6 screws.
  • Using the proper driver makes the screw removal simple and quick
  • All screws have the same length, no need to separate them.
Step 3

Repair step

  • Insert a small guitar pick or similar tool to separate the individual halves. Start by the charging port end since this seems to be a better entry and not quite as tight.
  • Continue to use the pick left and right of the charging port. As the pick advances, one can feel the separation of the adhesive.
  • Multiple passes along the sides of the halves will be necesarry
Step 4

Repair step

  • Continue to advance the tool around the joint. It will take multiple passes to loosen the adhesive.
  • Once the joint widens, a plastic opening tool can also be used.
  • Once loosened enough, try to separate the parts manually.
Step 5

Repair step

  • Try to remove it carefully but with some force
  • Do not pry just pull and move along.
  • As the halves separate the vast amount of black silicone like adhesive becomes evident
Step 6

Repair step

  • Finally opened and the silicone like adhesive is everywhere.
  • The battery is sandwiched between the logicboard and the bottom of the case.
  • The logic board is fastened to the case by two T6 screws
Step 7

Repair step

  • Both screws are the same length.
  • Lift the logic board gently of the case. Do not try to totally remove the board. There will be four wires that attach the board to the case as well as the battery cables.
  • With the board lifted remove the battery from the case. It is adhered with double sided tape and comes of relatively easy
Step 8

Repair step

  • Rotate the board with the battery to the side where the four cables attach to the case
  • Identify the solder points for the battery cables
  • Unsolder one wire
Step 9

Repair step

  • Then the next
  • remove the battery
  • Here is the battery finally removed. Replacements are not readily available. The battery dimensions are 1.9" x 0.75" x 0.16" and it is a 3.7V 400mAh Li-Ion battery.