DeWalt DWD112 Field Replacement

The wound wires of a field coil can fail,...

iFixit Library DeWalt DWD112 Moderate No estimate Guide 61432
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

The wound wires of a field coil can fail, causing a drill to function poorly or not at all. Use this guide to replace a broken field in the DeWalt DWD112.

Step 1

Repair step

  • Remove seven TR20 Torx Security screws from the side of the drill.
Step 2

Repair step

  • Remove the top cover to reveal the inside of the drill.
  • Set the top cover of the drill aside.
Step 3

Repair step

  • The power cord and the trigger act as a single part and must be replaced together.
  • Using one hand grab the trigger box and with the other grab the end of the wire connecting to the trigger box and disconnect the wire.
Step 4

Repair step

  • Disconnect the second connected wire from the top of the trigger box.
Step 5

Repair step

  • Lift the trigger box up to reveal the bottom side.
  • Disconnect the first connected wire from the bottom of the trigger box.
Step 6

Repair step

  • Disconnect the last wire from the trigger box using the same method from the previous step.
Step 7

Repair step

  • After all four wires are disconnected, the trigger and power cord are separated from the drill.
  • The power cord and trigger can be set aside if further disassembly is required.
Step 8

Repair step

  • Take note of the keyless chuck and the meshing of the gears.
Step 9

Repair step

  • Grab the metal chuck by the rotating spindle as if you are to tighten in a drill bit.
  • Lift the metal chuck out of its resting place and set aside.
Step 10

Repair step

  • With your left hand, grab hold of the field, which is the large metal block with coils looped around the inside.
  • Use your other hand to take the bearing out from the end of the gear connected to the armature.
Step 11

Repair step

  • Lift the field up once more with one hand and grab the cooling fan with the other hand and gently slide the armature out of the field.
  • The brushes will now be disconnected from the armature, meaning no current can flow from the power cord to the motor.
Step 12

Repair step

  • Move the black wire clear from any obstruction.
  • Repeat this step for the white wire and the red wire.
Step 13

Repair step

  • The field is disconnected from all other parts.
  • Grab the field and gently lift it out of the case.