FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

MacBook Air 13" Mid 2011 Fan Replacement

Use this guide to replace a dead or noisy fan.

iFixit Library MacBook Air 13" Mid 2011 Moderate 50 minutes Guide 6362
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Use this guide to replace a dead or noisy fan.

Step 1

Repair step

  • Before proceeding, power down your MacBook. Close the display and lay it on a soft surface, top-side down.
  • Use a P5 Pentalobe driver to remove ten screws securing the lower case, of the following lengths:
  • Two 9 mm screws
  • Eight 2.6 mm screws
Step 2

Repair step

  • Wedge your fingers between the display and the lower case and pull upward to pop the lower case off the Air.
  • Remove the lower case and set it aside.
Step 3

Repair step

  • As a precaution against accidental discharge or shock, disconnect the battery connector from the logic board.
  • Grab the clear plastic pull tab attached to the battery connector and pull it toward the front edge of the Air to disconnect the battery from the logic board.
  • Be sure to pull the connector horizontally toward the battery, and not straight up from the Air, or you may damage the socket on the logic board.
Step 4

Repair step

  • Use the flat end of a spudger to pry the I/O board cable connector upward out of its socket on the I/O board.
Step 5

Repair step

  • Carefully peel the I/O board cable from the top of the fan.
Step 6

Repair step

  • The following connector has an especially deep socket. Use care when disconnecting it.
  • While gently pulling the I/O board cable upward near its connection to the logic board, use the tip of a spudger to pry upward on alternating sides of the connector to help "walk" it out of its socket.
  • Remove the I/O board cable.
Step 7

Repair step

  • Use the tip of a spudger to carefully flip up the retaining flap on the fan cable ZIF socket.
  • Be sure you are prying up on the hinged retaining flap, not the socket itself.
Step 8

Repair step

  • Peel the rubber gasket off the adhesive on the top of the fan.
Step 9

Repair step

  • Remove the following three screws securing the fan to the upper case:
  • One 3.6 mm T5 Torx screw
  • One 2.7 mm T5 Torx screw
  • One 3.6 mm T5 Torx screw with a short head
Step 10

Repair step

  • Lift the fan out of the upper case and carefully pull the fan ribbon cable out of its socket as you remove it from the Air.