Guide overview

Before you begin

If your Magic Bullet NutriBullet Pro won't activate, and you have determined that the activators are the culprit, follow this guide to replace them. This guide will work to replace all three activators.

Step 1

Repair step

  • To start the disassembly of the Magic Bullet NutriBullet Pro you will begin from the bottom.
  • Flip the device over to the bottom.
  • Unscrew the four 1 cm screws using #2 Phillips Head Screwdriver.
  • Remove the loose bottom portion of the device by pulling up from the bottom.
Step 2

Repair step

  • Unscrew the two 1 cm screws holding down the power cord using the #2 Phillips Head Screwdriver.
Step 3

Repair step

  • Unscrew the three 1 cm screws on the device circled on the screws pictures using the #1 Philips Head Screwdriver.
  • Lift off the grey plastic piece off.
  • Slide off the silver metal piece.
Step 4

Repair step

  • Flip the device over.
  • Remove the three rubber seals covering the screws by pulling the components upward with the tweezer.
  • Unscrew the three 16 mm screws using the #2 Phillips Head Screwdriver.
Step 5

Repair step

  • Pull off the casing from the device.
Step 6

Repair step

  • Remove the two 8 mm screws using the #2 Phillips Head Screwdriver while holding the activator in place.
  • There are three separate activators with two screws each.
Step 7

Repair step

  • Be careful of the spring flying out.
  • Lift activator out of the Magic Bullet housing while holding the spring with tweezers.