FIXONIC
SellSavedMy Fixonic
Official iFixit API visual reference

Fahrenheit FHT 125PRMR Power Cord Replacement

Is the device not turning on when plug in? This...

iFixit Library Fahrenheit FHT 125PRMR Easy 5 minutes Guide 72934
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Is the device not turning on when plug in? This guide will help you replace the power cord to fix the issue.

Step 1

Repair step

  • Use your fingers or a plastic opening tool to open the side hinges on both sides of the device.
Step 2

Repair step

  • Using a Philips head #2 screwdriver remove the 7mm black screw from the hinge of the device.
Step 3

Repair step

  • Using the metal spudger, push through the hole the screw was removed from. Doing this will push the copper pin out of the other side.
  • When the pin is removed the two sides of the device can now separate.
  • Be sure to collect the spring that is next to the hinge when they are separated.
Step 4

Repair step

  • Use the Phillips Head 1 screwdriver to remove the two screws on the back where the power cable exits the device.
  • Once the two screws are removed; simply lift the case up and off to have access to the power cable.
Step 5

Repair step

  • To remove the power cable, grab the clear plastic holding and the base of the power cable and pull apart.