Domestic waterworks water bladder replacement

If the domestic waterworks briefly in a row...

iFixit Library Hauswasserwerk Moderate 1 hour Guide 78805
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

If the domestic waterworks briefly in a row always goes on and no pressure can hold more so usually the water bubble is broken, that is leaking. The water bubbles have they hold different life with me so 1-2 years, probably they are attacked by the corrosion of the boiler, much maybe a stainless steel boiler at this point would be better suited. I made the best experiences with the EDMP however only with the high quality membranes. The cheap are torn after 2 months or something like that.

Step 1

Preliminary work

  • Domestic waterworks make off, then close the shut-off valve from the water inlet. Then Depressurize the waterworks by the water from a tap.
Step 2

Open the boiler

  • Loosen the screws with a 13 mm ring spanner, caution it runs out the water. Best to make a bucket to catch the water including. Then remove the cover. You can see the old bag. This can now be removed. The water bag is very dirty, therefore it is recommended to dress gloves
Step 3

Swap water bubble

  • Remove the water bag. Now is still the remaining water from the leaky water bag in the boiler. With a hose through the rest of the water suction vacuum.
Step 4

Clean the boiler

  • The boiler then clean with old rags, since this has quite a rust deposits.
Step 5

Insert new water bubble

  • Install the new water bag and then screw the lid. The screws should be not to tight. Please make sure that the water bag is properly seated. Usually this is more curved on a page, this page comes down.
Step 6

connection work

  • With a compressor or even foot pump produce about 1.5 bar pressure in the boiler. There should be no water in it. Then re-open the supply and take the House water system in operation. Possible must be drawn on a $!^&* to fill the pump a little water.