Step 1

Repair step

  • Power the device down before taking any other actions.
  • Hold the camera with the lens facing towards youself.
  • Turn the camera upside down and place your right thumb on the battery chamber cover.
Step 2

Repair step

  • Hold the camera, then pull the battery chamber towards yourself with your right thumb.
  • Pull the cover entirely out and release it to reveal the battery.
Step 3

Repair step

  • Locate the orange battery latch that holds the battery in place.
  • Use your finger to push the latch away from yourself to release the battery.
  • Remove the battery manually from the battery chamber.
  • Place the battery into a charger if it is dead.
  • Remove battery before performing any other repairs.
Step 4

Repair step

  • Replace defective battery if previous steps fail
  • Contact support on the Fujifilm website for further assistance
Step 5

Repair step

  • Remove four 2.5mm Phillips #1 screws on the bottom of the camera near where the camera mount attaches.
  • Remove two 5.1mm Phillips #1 screws on the left side of the camera relative to the LCD screen.
  • Remove two 5.1mm Phillips #1 screws on the right side of the camera relative to the LCD screen nearest to the mode wheel.
Step 6

Repair step

  • Place the camera lens face down with the LCD screen face up on a flat surface, or hold it. Carefully lift the camera’s back cover approximately 1 inch.
  • Carefully lift the ribbon clamp connector back using the tweezers and remove the blue ribbon.
  • Do NOT pull on ribbon if the ribbon clamp connector still grasps the blue ribbon. This could cause severe damage to the ribbon.
  • If you are replacing the LCD monitor you can skip steps 6 and 7 for the selector button circuit board guide and go directly to the LCD monitor repair guide.
  • If you are replacing the Mode Dial you can skip steps 6 and 7 for the selector button circuit board guide and go directly to the Mode Dial repair guide.
Step 7

Repair step

  • Remove the back of the camera case and place it on a flat surface with the selector button circuit board facing up.
  • Remove the three 3.5mm Phillips #1 screws located on the chip seen in the image.
Step 8

Repair step

  • Lift the chip with tweezers to remove it from the other remaining components.