Canon Vixia HF R70 Shutter Replacement

Use this guide to remove and replace the...

iFixit Library Canon Vixia HF R70 Moderate 10 minutes Guide 87513
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

Use this guide to remove and replace the shutter to your Canon Vixia HF R70.

Step 1

Repair step

  • Power off and unplug the device.
  • Position the camera so that the battery is facing you.
Step 2

Repair step

  • Locate the latch on the bottom edge of the camera.
  • Hold the battery into place and gently push down on the latch towards the lens.
Step 3

Repair step

  • While holding down the latch, remove the battery by pulling it out of the device.
Step 4

Repair step

  • Position the camcorder so that the wrist strap is facing you.
  • Locate the loose end of the strap.
Step 5

Repair step

  • Gently pull on the loose end to separate the Velcro.
Step 6

Repair step

  • Locate the "slot" on bottom right corner of the camcorder where the strap loops through.
  • Pull the strap through the loop.
Step 7

Repair step

  • Pull the strap through the leather cushion.
Step 8

Repair step

  • Pull the strap through the slot on the left side of the camcorder.
Step 9

Repair step

  • Position the camcorder so that the side panel is facing you.
  • Locate the two 6mm Phillips #00 screws on the side panel.
  • Remove the the screws using a screwdriver with a Phillips #00 head.
Step 10

Repair step

  • Turn the camcorder so that the bottom is facing you.
  • Using your screwdriver, locate and remove the four 6mm Phillips #00 screws connecting the side panel to the bottom of the camcorder.
Step 11

Repair step

  • Gently remove the side panel by pushing it up from the bottom.
Step 12

Repair step

  • Disconnect the wires by inserting the plastic opening tool into the small slit.
  • Begin to push upward with the plastic opening tool, disconnecting the two compartments.
Step 13

Repair step

  • Disconnect the four ZIF connectors by grasping the connector firmly and pulling gently.
Step 14

Repair step

  • Locate and remove the two 3mm Phillips #00 screws on the side of the camera where the side panel was removed.
Step 15

Repair step

  • Turn the camera over to the side with the LCD screen, and open the screen.
  • Locate and remove the three 5mm Phillips #00 screws holding the top panel in place.
Step 16

Repair step

  • Pull the panel up and away until it is removed completely.
Step 17

Repair step

  • There are three 5mm Phillips #00 screws that need to be removed - one on the top, one on the side, and one on the bottom.
  • Locate and remove the screw on the top side of the camera.
  • Locate and remove the screw on the side of the camera where you previously removed the side panel.
  • Locate and remove the screw on the bottom of the camera.
Step 18

Repair step

  • Pull the entire shutter away from the body of the camera to remove it.