Step 1

CHECKING OF THE TEMPERATURE

  • Check the nozzle and bed temperature after power on the machine. Both temperature should be in between 30 to 40 degree before preheat. It is the room temperature.
  • If the temperature showing is below or too much above the room temperature, that means that any problem in heater or thermistor.
Step 2

HOW TO CHECK THERMISTOR?

  • Remove the thermistor connection from the printer board of the nozzle.Remove the wire connector of the thermistor.
  • Take a multimeter and connect in the thermistors two leg by putting the multimeter knob into resistance value.
  • If the thermistor is showing a value of above 60 ohm means, it is working. Else you have to change the thermistor and connect it back in the same way. And go to next step.
Step 3

CHECKING CONTINUITY OF WIRE

  • Take the connecting wire of thermistor with connector at one end.
  • Take the multimeter, connect the prob of multimeter on the two ends of the wire and also go for continuity test option in the multimeter.
  • If it is having continuity, the multimeter will produce a beep sound, else we can understand the wire has to be changed.
Step 4

RECONNECTION AND CHECKING

  • After checking these things , reconnect the thermistor connection.
  • Now go to prepare
  • click preheat
Step 5

CHECKING TEMPERATURE

  • Go to main menu, you can see the temperature is increasing or not.
  • If it is incresing, it means the nozzle is working.