This guide describes opening a Withings Smart Body Analyzer and cleaning the PCB after water ingress. On my device, the display remained black. I therefore looked for a way to open the housing without heating the glass plate.

Step 1

Open the balance

  • Since it is not important in the balance to get the adhesive surfaces take a beveled spatula. It's much easier and faster.
Step 2

Repair step

  • Contrary to the other instructions, the board is located directly on the plastic housing. Through the 3 holes water gets into the balance and through the adhesion it spreads over the complete underside of the board
  • The Libra continues to change. Only this time too much water had penetrated which had spread under the board.
  • Clean the underside of the board with acetone. Alternatively, isopropanol.
  • After the board was dry, the scales spoke to me again. And so that water does not penetrate again, I taped the holes with silicone
  • Finally, glue the round cap to the glass plate with a little silicone glue. Because even if the board has a silicone protective coating, it would not be good if Wassser came from above on the SMD components.