Before you begin

Replace the light tunnel if experiencing dark bands across or on the edges of the screen. For this project you'll need a can of compressed air to clean the inside if it's dirty. You'll also need a Torx screwdriver and a metal spudger.

Step 1

Repair step

  • Flip the projector on its back.
  • Use the Phillips #2 screwdriver to remove the (4) four 2 cm gold screws.
  • Use the Phillips #2 screwdriver to remove the (3) three 1 cm silver screws.
Step 2

Repair step

  • Turn the projector, facing the back cable board towards you.
  • Using the Phillips #0 screwdriver, remove the (3) three 1.0 cm silver screws on the back panel.
  • Gently take off back cable panel.
Step 3

Repair step

  • Turn the projector so the front side with the lens is facing you.
  • Gently pry the both of the grey lens rings using the metal spudger.
Step 4

Repair step

  • Now that the screws have been removed, proceed with the removal of the outer panel.
  • Gently remove the front lens panel.
  • Be forewarned, the panel will resist. Be careful not to break the lens.
Step 5

Repair step

  • Being careful not to pull the wires inside the projector, gently lift the top panel off the projector.
  • Rest the lid behind the projector so the insides are exposed and undamaged.
Step 6

Repair step

  • With the lens facing you, remove the following screws:
  • Using the Phillips #1 screwdriver, remove the (3) three 1.25 cm gold screws holding the metal grate between the color wheel unit and the bulb.
  • Using the Phillips #1 screwdriver, remove the (2) two 2 cm gold screws on the right side of the lens house.
  • Using the Phillips #1 screwdriver and a bent driver, remove the (4) four 2 cm screws on the back of the lens house.
Step 7

Repair step

  • Using a Phillips #0 screwdriver remove the three 1 cm black screws from the lens house.
  • Remove the lens unit.
Step 8

Repair step

  • Using the Phillips #0 head, unscrew the four 1 cm black screws.
  • Remove the metal casings holding the tunnel in place.
Step 9

Repair step

  • Using the Phillips #0 head, unscrew the black 0.5 cm screw on the bottom of the lens house.
  • Remove the light tunnel.