Samsung Gear VR Inner Mask Replacement

The inner mask lies under the phone mount and...

iFixit Library Samsung Gear VR Moderate 5 - 10 minutes Guide 99277
Open the authorised source
Licensed iFixit integration

This attributed iFixit guide is displayed through Fixonic's recorded commercial API permission. iFixit remains the independent source and author of the procedure.

Guide overview

Before you begin

The inner mask lies under the phone mount and requires removal in order to access the lenses and focus wheel assembly. This guide will instruct the user on how to remove the mask from the headset. The motherboard partially sits on the inner mask piece of the headset and must be removed in order to remove the inner mask piece. Caution is required while working on the headset as a wire harness connects the USB adapter to the motherboard. Care should be taken not to put any strain on the wire and to open the headset from right to left.

Step 1

Repair step

  • Remove the front cover to access a plate that holds the phone in place during use.
  • Remove the four corner screw covers with a metal spudger to reveal four screws.
  • Remove the sticker located at the top center to reveal two additional screws.
Step 2

Repair step

  • Using the PH000 tip remove the six 0.5 cm screws that secure the front phone mount.
  • After the six 0.5 cm screws are completely removed lift the front phone mount up and to the left.
  • When handling your equipment be careful not to strain the wire harness located on the left side of the headset.
Step 3

Repair step

  • Use the blue plastic opening tool to remove the rest of the the pop connectors from the motherboard.
  • The larger gold connector is lightly glued down so it may take more effort to remove than the others.
Step 4

Repair step

  • You can now remove the motherboard from the mask.
  • Make sure that nothing is connected to the motherboard before you try to remove it as pulling it with something connect might brake the connections.
Step 5

Repair step

  • Using the PH000 tip remove the eight 0.5 cm screws from the Inner Mask
  • Carefully remove the Inner Mask by pulling it from the inner side of the lenses socket.